VIX™ · patented

The most energy-efficient cleanroom concept

Our patented VIX concept delivers stronger airflow control and operational reliability, at a fraction of the energy.

Up to70%
lower energy use
99.995%
uptime
How it works

All air treatment in one integrated plenum

Filtration, fan units and air conditioning sit together in one module above the cleanroom. No separate mechanical rooms, no complex ducting. Less space, faster installation. VIX is a core part of the ADAPTUS product platform.

Go as you growAdd modules without stopping production
99.995% uptimeModules are serviced while the room keeps running
UpgradableUpgrade filtration and control step by step

VIX versus traditional cleanrooms

Traditional

Higher energy use, single point of failure

A central air handling unit pushes large volumes through long ducts at a fixed, high airflow, regardless of demand. If it fails, the whole cleanroom stops.

VIX

Continuous operation, easy upgrades

Multiple compact modules in a sealed ceiling plenum, with sensor-driven control matching airflow to demand. Service one module while the others keep running. Add modules to raise capacity or class.

Reference case

Where the savings come from

Switching from a centralised system to modular VIX. *Results depend on process loads, operating hours and energy prices.

Planned downtime costs
83%
Recirculation air costs
75%
Heating costs
62%
Dehumidification costs
61%
Cooling costs
59%
15-year total costs
44%
Unplanned downtime
33%

Why companies choose VIX

Lower total cost of ownership

Less energy, optimised airflow and less maintenance.

Fewer production stops

Modules are serviced while the room keeps running.

Easy to expand

Grow without disrupting ongoing operations.

Sustainable by design

Less energy, less material, optimised airflow.

Built for minimal leakage

Follows VCCN guideline RL 8 and achieves airtightness class L2, so less fresh air is needed to hold pressure cascades.

Smarter fresh air management

Integrated CO₂ monitoring keeps indoor air below 750 ppm. Traditional cleanrooms often supply about 20% fresh air that must be fully treated.

Product families

Choose your configuration

10 to 15 weeks

INTEGRA

Off-the-shelf modular cleanroom meeting ISO and cGMP standards through the integrated VIX concept.

16 weeks

VIX

Integrated airflow and plenum solution with decentralised air units.

Contact

Let's talk VIX

Pre-engineered building blocks, circular design, validation, GMP monitoring, commissioning or remodelling: our team answers quickly and to the point.